Battery Life Calculator in Watts
Calculate battery endurance from total load wattage, including inverter efficiency losses and Depth of Discharge.
A multimeter reading tells you more than you might think. This battery life calculator by voltage turns a resting voltage into an estimated state of charge, then works out how many amp-hours and hours of runtime you have left before it’s time to recharge.
| Charge | Resting voltage |
|---|
Pick your battery type and system voltage, enter the resting voltage you measured, then add the battery’s capacity and your load. The calculator estimates state of charge from the voltage and turns the usable amp-hours left into runtime.
Battery type. Each chemistry has its own voltage curve, so the same reading means different things on lead-acid and lithium. Choose flooded, AGM/gel, LiFePO4 or lithium-ion.
System voltage. The nominal voltage of the battery or bank: 12 V, 24 V or 48 V for most lead-acid and LiFePO4 systems, or the series cell count (such as 3S or 10S) for lithium-ion packs.
Measured resting voltage. Read it with a multimeter across the terminals after disconnecting loads and chargers. Lead-acid needs several hours to settle (overnight is best); lithium usually settles within 30–60 minutes.
Capacity and load. Enter the rated amp-hours and the load in amps or watts. Watts are converted to amps using the system’s nominal voltage.
Recharge point. The lowest state of charge you want to reach. Stopping at 50% greatly extends lead-acid life; lithium batteries can safely go to 10–20%.
The top figure is the estimated state of charge. Runtime until recharge point is how long your load can run before the battery reaches the level you set. Charge remaining is the total amp-hours left; usable before recharge point is only the part above your limit. If your reading is above “full” or below “empty”, a note explains what that usually means.
A battery’s resting (open-circuit) voltage rises and falls predictably with its charge level. The calculator finds your reading on a typical voltage-to-charge curve for the chosen chemistry, interpolates between the nearest points, and converts the charge above your recharge point into runtime.
V Your measured resting voltage, in voltsVlow, Vhigh The chart voltages just below and above your reading, with their charge levels SoClow and SoChighSoC Estimated state of charge, in percentC Rated capacity, in amp-hours (Ah)SoCstop Your recharge point, in percentI Load current in amps; P is load in watts and Vnom the nominal system voltageA 100 Ah flooded lead-acid battery reads 12.50 V after resting overnight. It will power a 5 A load, and you want to recharge at 50%.
| State of charge | Flooded lead-acid | AGM / Gel | LiFePO4 (12.8 V) |
|---|---|---|---|
| 100% | 12.73 V | 12.85 V | 13.60 V |
| 80% | 12.50 V | 12.65 V | 13.30 V |
| 50% | 12.10 V | 12.30 V | 13.15 V |
| 20% | 11.66 V | 11.96 V | 12.90 V |
Why a voltage-based estimate can drift:
Watts are converted with nominal voltage, state of charge is shown to the nearest whole percent, and runtime to the nearest minute.
What battery voltage tells you about charge level, and where it falls short.
At rest, about 12.7 V for flooded lead-acid, 12.8–12.9 V for AGM, and roughly 13.4–13.6 V for a 12 V LiFePO4 battery. Higher readings straight after charging are surface charge and settle over the next few hours.
Around 12.1 V for flooded lead-acid and about 12.3 V for AGM. For LiFePO4, 50% sits near 13.1–13.2 V, but the curve is so flat in the middle that the figure is much less reliable.
You can get a reasonable estimate if the battery has rested and you know its chemistry. Readings taken under load, straight after charging, or on a lithium battery in its flat middle range can mislead, so a shunt-based battery monitor is the better tool for precise tracking.
Every battery has internal resistance, so current flow causes a voltage sag that recovers once the load stops. That’s why the calculator asks for a resting voltage: a reading under load makes the battery look emptier than it is.
Yes, a little. The curves here assume about 25 °C (77 °F). Temperature shifts resting voltage slightly, and cold also reduces how much capacity the battery can deliver, so in winter treat the runtime estimate as optimistic.
Set a digital multimeter to DC volts, disconnect loads and chargers, let the battery rest, then touch the probes straight to the terminals, red to positive. Measuring at the terminals rather than at a distant outlet keeps wiring losses out of the reading.
Explore our companion calculators designed for different battery metrics, voltage curves, and duty-cycle load profiles.
Calculate battery endurance from total load wattage, including inverter efficiency losses and Depth of Discharge.
Estimate runtime from amp-hour capacity and continuous draw, compensated for high-rate Peukert discharge losses.
Determine usable runtime and total recharge cycles for watt-hour rated batteries and portable power banks.
Simulate micro-amp power budgets for embedded microcontrollers with complex active and sleep duty cycles.