Battery Life Calculator in Ah
Estimate runtime from amp-hour capacity and continuous draw, compensated for high-rate Peukert discharge losses.
Know what your devices draw in watts? This battery life calculator in watts turns your list of loads into hours of runtime, allowing for inverter losses and for how deeply you can safely drain the battery.
Estimate only. Cold weather, battery age and heavy loads can shorten real runtime.
To use the battery life calculator in watts, enter your battery’s voltage and amp-hour rating, list each device with its wattage, then set the inverter efficiency and how much of the battery you’re willing to use. Runtime updates as you type.
Enter the battery voltage. Use the nominal voltage on the label: 12 V for most lead-acid batteries, 12.8 V for a 12-volt LiFePO4, or 24 V and 48 V for larger banks. Batteries wired in series add their voltages together.
Enter the capacity in amp-hours. This is the Ah rating printed on the battery. Batteries in parallel add their amp-hours, so two 12 V 100 Ah batteries in parallel act as one 12 V 200 Ah battery.
List your loads in watts. Give each device a name, its wattage and how many you have. Use average draw rather than peak: a fridge compressor switches on and off, so its average is well below the number on the sticker.
Set the efficiency. Leave it at or near 100% for DC devices wired directly to the battery. For anything plugged into an inverter, 85–90% is a realistic figure.
Choose the usable depth of discharge. Lead-acid and AGM batteries last much longer if you stop at about 50%. Lithium batteries handle 80–90% or more without trouble.
The headline figure is how long the battery can carry your whole load list before it reaches the depth of discharge you set. Underneath, total load adds up every device, battery current shows the amps flowing out of the battery (handy for fuse and cable sizing), and energy delivered is the share of watt-hours that actually reaches your devices.
The calculator converts your battery’s amp-hour rating into stored energy in watt-hours, removes the part you shouldn’t use and the part lost in conversion, and divides what’s left by your total load in watts.
V Nominal battery voltage, in volts (V)Ah Rated battery capacity, in amp-hoursDoD Usable depth of discharge as a decimal (90% = 0.9)η Inverter or converter efficiency as a decimal (90% = 0.9)P Total load in watts (W): each device’s watts × quantity, added upA 12.8 V 100 Ah LiFePO4 battery runs a 60 W fridge, a 45 W laptop charger and three 5 W LED lights through an inverter. Settings: 90% DoD, 90% efficiency.
A few things push real runtime away from the formula:
The calculator uses nominal voltage throughout and rounds runtime to the nearest minute, so treat the result as a planning figure rather than a guarantee.
Straight answers on watt-based runtime, inverter losses and sizing a battery for real loads.
Roughly 5.4 hours on a lead-acid battery and about 9.7 hours on lithium, assuming the load runs through a 90% efficient inverter. The battery stores 1,200 Wh (12 V × 100 Ah), but you should only use about 50% of a lead-acid battery, compared with around 90% of a lithium one.
Divide watts by battery voltage: amps = watts ÷ volts. A 120 W load on a 12 V battery draws 10 A, or about 11.1 A once a 90% efficient inverter is in the path. The calculator shows this as battery current, which also helps when you size fuses and cables.
Use the actual average watts whenever you can. Nameplate ratings are usually maximums, so they make runtime look shorter than it will be. A plug-in power meter gives a better number, and for appliances that cycle on and off, such as fridges, average the draw over a full hour.
Not automatically, but you can add it as its own line. Look up the no-load power in the inverter manual (or multiply its no-load current by battery voltage). With small loads, idle draw can use a surprising share of the battery.
It’s a solid planning estimate when your wattage figures are realistic. Real runtime usually comes in a little lower because of cold temperatures, battery age and voltage sag under heavy loads, so leave a 10–20% margin for anything critical.
Yes, for the time the battery runs on its own. Enter your loads, then raise or lower the amp-hours until the runtime meets your target. It doesn’t count solar or charger input during the run, so it shows a worst case for cloudy days or outages.
Explore our companion calculators designed for different battery metrics, voltage curves, and duty-cycle load profiles.
Estimate runtime from amp-hour capacity and continuous draw, compensated for high-rate Peukert discharge losses.
Determine usable runtime and total recharge cycles for watt-hour rated batteries and portable power banks.
Translate resting multimeter voltage readings into state of charge (SoC %) and remaining operational runtime.
Simulate micro-amp power budgets for embedded microcontrollers with complex active and sleep duty cycles.